007-17-30V-0.5F

  • Bonded and crosslinked
  • Medium polarity
  • Comparable to OV-17
  • Similar phases: DB-17, Rtx-50, SPB-50, AT-50, HP-17, HP-50+, CPSil-20CB
  • USP Phase Specification: G3
$755.00
 

General area of use

pesticides, phenols, pharmaceuticals, FAMEs. etc

007-17 is a 50% phenyl methylpolysiloxane phase. The presence of the 50% phenyl groups increases the overall "polarity" of the phase and enhances the selectivity of induced dipole interactions resulting in greater retention of aromatic solutes. The 007-17 phase is widely used as an EPA Method confirmation column and provides for efficient separations of PAHs, and biomedical samples such as drugs, sugars and steroids.

007-17, (50% Phenyl) Methylpolysiloxane columns are available in all standard column I.D.'s and lengths. The film thickness ranges are noted in the chart below.

Specifications:

I.D.10M.15M.25M.30M.50M.60M.75M.100M.STANDARD FILM THICKNESS RANGE
0.10mm                 0.1 - 0.25µm
0.18mm                 0.1 - 0.5µm
0.25mm                 0.1 - 1.0µm
0.32mm                 0.1 - 3.0µm
0.53mm                 0.1 - 3.0µm
Inquire with tech@quadrexcorp.com about custom lengths and films.

 

007-17 OPERATING TEMPERATURE RANGE
film thickness temperature range
up to 1.0µm 40° C to 325° C
2.0 to 3.0µm up to 300°C

 

007-17 BONDED PHASE RETENTION INDEX
benzene 1-nitropropane 2-pentanone pyridine butanol
780.95 920 800 925 721

Hot tip:

Don't see a length or film thickness that you require?

Contact us - we do custom configurations all the time!

PCB's, pesticides, alcohols, pharmaceuticals

007-17 is a 50% phenyl methylpolysiloxane phase. The presence of the 50% phenyl groups increases the overall "polarity" of the phase and enhances the selectivity of induced dipole interactions resulting in greater retention of aromatic solutes. The 007-17 phase is widely used as an EPA Method confirmation column and provides for efficient separations of PAHs, and biomedical samples such as drugs, sugars and steroids.

007-17, (50% Phenyl) Methylpolysiloxane columns are available in all standard column I.D.'s and lengths. The film thickness ranges are noted in the chart below.

Specifications:

I.D.10M.15M.25M.30M.50M.60M.75M.100M.STANDARD FILM THICKNESS RANGE
0.10mm                 0.1 - 0.25µm
0.18mm                 0.1 - 0.5µm
0.25mm                 0.1 - 1.0µm
0.32mm                 0.1 - 3.0µm
0.53mm                 0.1 - 3.0µm
Inquire with tech@quadrexcorp.com about custom lengths and films.

 

007-17 OPERATING TEMPERATURE RANGE
film thickness temperature range
up to 1.0µm 40° C to 325° C
2.0 to 3.0µm up to 300°C

 

007-17 BONDED PHASE RETENTION INDEX
benzene 1-nitropropane 2-pentanone pyridine butanol
780.95 920 800 925 721

Hot tip:

Don't see a length or film thickness that you require?

Contact us - we do custom configurations all the time!

More Information
Application

APPLICATIONS:

Click below to view 007-17 chromatograms on the web:

Phase Code 007-17
Film (microns) 0.5um
Phase Type 50% phenyl methylpolysiloxane
Phase Code 007-17
Column Length (M.) 30M.
Column ID (mm) 0.53mm
Film (microns) 0.5um
Phase Type 50% phenyl methylpolysiloxane

APPLICATIONS:

Click below to view 007-17 chromatograms on the web:

Quadrex © 2021. All Rights Reserved

Secure Payments Method payment methods