#SRI-8610-0040-1, #SRI-8610-0040-2

SRI PRECONFIGURED GC SYSTEMS - GREENHOUSE GAS GC

  • ECD and FID-Methanizer detectors
  • 10-port gas sampling valve and valve oven
  • On-column injector
  • 4-channel Peaksimple data system
  • Dual packed columns

The Greenhouse Gas GC is designed for the detection of carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O). Depending upon the volume of the sample loop on the gas sampling valve, it can detect trace levels or high concentrations. It may be used for stack or ambient air monitoring, or in a plane for atmospheric air analysis.

The Greenhouse GC is not limited to CO2, CH4 and N2O. The FID-Methanizer detects hydrocarbons as well as CO and CO2 (as methane). The sensitive ECD detector responds to electronegative compounds, especially chlorinated, fluorinated, or brominated molecules like PCBs and pesticides. With a low-volume sample loop, the Greenhouse GC can be used to measure gases produced by bacterial metabolic processes and life cycles.

Options & Upgrades: additional detectors, additional sample loops, 6 channel USB PeakSimple data system

$20,079.00
 

SRI PRECONFIGURED GCs

SRI full-featured Portable GCs are ideal for use in the field, as well, and they are equally comfortable on a lab bench. You can customize a GC system to meet your specific analytical needs with a wide range of injectors, detectors, and accessory options.

Due to the popularity of some configurations, a number of pre-configured GCs are offered satisfying a wide range of common analytical applications. In some cases, the preconfigured GCs are less expensive than the identical hardware assembled "a la carte." Each of the preconfigured GCs may be further customized (except the educational GC systems).

Check out these popular pre-configured systems below, or configure your own system to meet your needs.

Hot tips:

Up to five injectors can be mounted on the 8610c GC Mainframe. Due to limited space, only a single injector can be mounted on the 310 GC Mainframe.

In order to add a second injector, of any type, additional cold on-column injector hardware must be added first. This hardware is then upgraded to the appropriate injector type.

Preconfigured gcs take advantage of batch manufacturing, offering a lot of gc power at very reasonable pricing.