#SRI-8610-5400-1, #SRI-8610-5400-2

SRI PRECONFIGURED GC SYSTEMS - CAPILLARY FID GC

  • FID Detector
  • Built-in air compressor
  • On-Column injector
  • 1-Channel Peaksimple data System
  • 30 Meter capillary column

The Capillary FID GC is a general purpose temperature programmable GC at very affordable pricing. This GC is equipped with the FID, a standard cold on-column injector for 0.53mm ID capillary or 1/8" packed columns, a built-in air compressor which supplies the FID combustion air, a 30 meter non-polar column, and Peaksimple Data Acquisition software.

You can upgrade this GC with a heated split/splitless injector for 0.32 or smaller capillary columns, a stand-alone hydrogen generator for the FID fuel, or a 20-vial liquid autosampler, etc.

Options & Upgrades: additional detectors with 4 channel serial or 6 channel USB PeakSimple data system, Split/Splitless and PTV injectors, Methanizer, gas sampling valves, columns

$8,749.00
 

SRI PRECONFIGURED GCs

SRI full-featured Portable GCs are ideal for use in the field, as well, and they are equally comfortable on a lab bench. You can customize a GC system to meet your specific analytical needs with a wide range of injectors, detectors, and accessory options.

Due to the popularity of some configurations, a number of pre-configured GCs are offered satisfying a wide range of common analytical applications. In some cases, the preconfigured GCs are less expensive than the identical hardware assembled "a la carte." Each of the preconfigured GCs may be further customized (except the educational GC systems).

Check out these popular pre-configured systems below, or configure your own system to meet your needs.

Preconfigured gcs take advantage of batch manufacturing, offering a lot of gc power at very reasonable pricing.

Hot tips: Up to five injectors can be mounted on the 8610c GC Mainframe. Due to limited space, only a single injector can be mounted on the 310 GC Mainframe. In order to add a second injector, of any type, additional cold on-column injector hardware must be added first. This hardware is then upgraded to the appropriate injector type.

Hot tips: Up to five injectors can be mounted on the 8610c GC Mainframe. Due to limited space, only a single injector can be mounted on the 310 GC Mainframe. In order to add a second injector, of any type, additional cold on-column injector hardware must be added first. This hardware is then upgraded to the appropriate injector type.

Hot tips:

Up to five injectors can be mounted on the 8610c GC Mainframe. Due to limited space, only a single injector can be mounted on the 310 GC Mainframe.

In order to add a second injector, of any type, additional cold on-column injector hardware must be added first. This hardware is then upgraded to the appropriate injector type.

More Information
Selections Preconfigured systems
Volts 110V
Details CAPILLARY FID GC
Selections Preconfigured systems
Volts 110V
Quadrex © 2021. All Rights Reserved

Secure Payments Method payment methods