#SRI-8610-0080-1, #SRI-8610-0080-2

SRI PRECONFIGURED GC SYSTEMS - PCB GC

  • FID/DELCD combo detectors
  • Thermal desorber
  • Built-in air compressor
  • 30M. Capillary Column
  • 4-channel Peaksimple data system

The SRI PCB GC has everything needed to detect PCBs in soil and other solid matrices. The Thermal Desorber permits the user to inject and analyze PCBs with very high sensitivity and little or no sample preparation - no solvent extraction is required. Up to 1 gram of soil can be loaded into each re-usable glass desorption tube.

The FID detector responds to all hydrocarbons, while the DELCD identifies which are halogenated. Due to the extreme selectivity of the DELCD, PCBs can be discriminated even in the presence of massive hydrocarbon contamination. The DELCD is protected from hydrocarbon contamination because the FID pre-combusts the sample.

The PCB GC system is also useful for detecting pesticides, PAHs, JP-4, kerosene, and diesel in soil. Soil samples are typically 20-50% water, so the FID flame is automatically relit after a large water peak. The 30-meter capillary column is included to efficiently separate hydrocarbons up to C40+. The built-in, "whisper-quiet" air compressor provides an infinite supply of combustion air for the FID/DELCD detector, and if the GC is used with the H2-50XR hydrogen generator, no gas cylinders are required.

Options & Upgrades: additional detectors, 6 channel USB PeakSimple data system, Split/Splitless and PTV injectors

$15,959.00
 

SRI PRECONFIGURED GCs

SRI full-featured Portable GCs are ideal for use in the field, as well, and they are equally comfortable on a lab bench. You can customize a GC system to meet your specific analytical needs with a wide range of injectors, detectors, and accessory options.

Due to the popularity of some configurations, a number of pre-configured GCs are offered satisfying a wide range of common analytical applications. In some cases, the preconfigured GCs are less expensive than the identical hardware assembled "a la carte." Each of the preconfigured GCs may be further customized (except the educational GC systems).

Check out these popular pre-configured systems below, or configure your own system to meet your needs.

Hot tips:

Up to five injectors can be mounted on the 8610c GC Mainframe. Due to limited space, only a single injector can be mounted on the 310 GC Mainframe.

In order to add a second injector, of any type, additional cold on-column injector hardware must be added first. This hardware is then upgraded to the appropriate injector type.

Preconfigured gcs take advantage of batch manufacturing, offering a lot of gc power at very reasonable pricing.