007-1701-25V-6.0F
- Bonded and crosslinked
- Moderately polar
- Comparable to OV-1701
- Similar phases: DB-1701, Rtx-1701, SPB-1701, AT-1701, HP-1701, BPX-1701
- USP Phase Specification: G46
General area of use
PCB's, pesticides, alcohols, pharmaceuticals
007-1701 is a (14% cyanopropylphenyl) methylpolysiloxane phase. The cyanopropyl functional groups provide a permanent dipole selectivity different from the induced dipole interactions of the phenyl groups. The overall "polarity" of this phase remains nominal when compared to the more highly cyanopropyl substituted phases such as 007-225 and 007-23. The 007-1701 phase is often used for solvents, pharmaceuticals, derivitized sugars and many environmental applications.
007-1701, (14% Cyanopropylphenyl) Methylpolysiloxane columns are available in all standard column I.D.'s and lengths. The film thickness ranges are noted in the chart below.
Specifications:
I.D. | 10M. | 15M. | 25M. | 30M. | 50M. | 60M. | 75M. | 100M. | STANDARD FILM THICKNESS RANGE |
---|---|---|---|---|---|---|---|---|---|
0.10mm | 0.1 - 0.25µm | ||||||||
0.18mm | 0.1 - 0.5µm | ||||||||
0.25mm | 0.1 - 1.0µm | ||||||||
0.32mm | 0.1 - 3.0µm | ||||||||
0.53mm | 0.1 - 5.0µm | ||||||||
Inquire with tech@quadrexcorp.com about custom lengths and films. |
007-1701 OPERATING TEMPERATURE RANGE | |
---|---|
film thickness | temperature range |
up to 1.0µm | -20° C to 280° C |
2.0 to 3.0µm | up to 260°C |
007-1701 BONDED PHASE RETENTION INDEX | |||||
---|---|---|---|---|---|
benzene | 1-nitropropane | 2-pentanone | pyridine | butanol | |
725.81 | 882.76 | 774.19 | 848.28 | 764.52 |
Hot tip:
Don't see a length or film thickness that you require?
Contact us - we do custom configurations all the time!
Application | APPLICATIONS:The chemist who originally developed the 1701 phase was watching the TV show Star Trek one night and named his phase after the designation of the Starship Enterprise: NCC-1701. Click below to view 007-1701 chromatograms on the web: |
---|---|
Phase Code | 007-1701 |
Film (microns) | 1.0um |
Phase Type | 14% cyanopropylphenyl methylpolysiloxane |
Phase Code | 007-1701 |
Column Length (M.) | 25M. |
Column ID (mm) | 0.53mm |
Film (microns) | 1.0um |
Phase Type | 14% cyanopropylphenyl methylpolysiloxane |
APPLICATIONS:
The chemist who originally developed the 1701 phase was watching the TV show Star Trek one night and named his phase after the designation of the Starship Enterprise: NCC-1701.
Click below to view 007-1701 chromatograms on the web: